EISNER::GUDEWICZ "Dave Gudewicz-CARTS LUG Chair"               23-JUL-1996 11:23
                             -< DTSS/UCX update >-
--------------------------------------------------------------------------------
    re: -1
    
    I did pull the DTSS bits out of extensions and set it up manually.  Its
    been working fine for over a year now.
    
    It also seems that NTP is working OK with UCX v3.3.  Other Vaxen here
    running MultiNet _seem_ to be getting the correct time from the Vax
    that's running DTSS and UCX.  I set the Vax with the Heath WWV clock
    and DTSS to NTP Strata 1.
    
    One thing I discovered about the Heath clock (Model GCW-1000-H) is that
    it can't be set to a year beyond 1999!  Something to think about if you
    own one of these devices.  Believe it or not Heath sells a newer
    version of this clock (at least they did a few months ago), but its a
    10Mhz only receiver and does **not** output the year, as its older model
    brother did.
    
    If I learn more on this, I'll post it here.
    
    Dave...
                                         

     